Is aluminum wiring in a house a fire hazard?

Which homes have aluminum branch wiring, what CPSC found about its fire risk, the warning signs and the three repairs CPSC accepts as permanent.

Updated November 25, 2026 · 6 official sources
On this page: 6 sections
  1. 1When was aluminum wiring used in homes?
  2. 2Why is aluminum wiring a fire hazard?
  3. 3What are the warning signs of aluminum wiring problems?
  4. 4How can you tell if a house has aluminum wiring?
  5. 5What repairs does CPSC accept as permanent?
  6. 6Is aluminum wiring still considered a fire risk?

Yes: a national survey for the U.S. Consumer Product Safety Commission (CPSC) found that homes built before 1972 and wired with aluminum were 55 times more likely than homes wired with copper to have one or more wire connections at outlets reach "Fire Hazard Conditions".1

When was aluminum wiring used in homes?

A shortage of copper in the mid 1960s caused builders to increase their use of aluminum wire in home electrical systems, moving it from the few large-power circuits for electric clothes dryers and ranges to general purpose 15- and 20-ampere-rated circuits. Homes built before 1965 are unlikely to have aluminum branch circuit wiring, while electrical cables installed between 1965 and the mid 1970s in new homes, in additions and as part of rewired or new circuits may contain aluminum wiring.1

An estimated 2 million homes were built with aluminum wire between 1965 and 1973.2 The 1974 CPSC release on aluminum wiring counted an estimated two million homes and mobile homes constructed using aluminum wiring since 1965.3 Aluminum conductors go back much further than those homes: they were first formally recognized in the 1901 edition of the National Electrical Code.4

The repairs in CPSC's Publication 516 don't apply to the larger gauge aluminum wire circuits and connections used for service entrance cables, electric clothes dryers and cooking ranges.1

Why is aluminum wiring a fire hazard?

The fire hazard CPSC investigated occurs at connections with aluminum wire, including receptacles, switches and junction boxes, and the hazard also occurs with major appliances like dishwashers or furnaces. Several deterioration processes in aluminum wire connections cause increased resistance to the flow of electric current, and the resulting damage is cumulative in effect. The increased resistance causes overheating, sometimes at hazardous levels, when current is flowing in the circuit.1

"Fire Hazard Conditions" in the CPSC survey meant receptacle cover plate mounting screws reaching 149°C (300°F), sparks emitted from the receptacle, or charred materials around the receptacle. The survey covered only wire connections at outlets and not the other aluminum wire connections and splices in homes that are also prone to fail, and the survey developed no information for aluminum-wired homes built after 1972.1

On April 28, 1974, two people died in a home in Hampton Bays, N.Y., and fire officials determined that the fire was caused by an overheating aluminum wire connection at a wall receptacle.1 A failure in 15- and 20-ampere aluminum wiring circuits can lead to electrical arcing and a serious fire, which can spread within the walls of a home before being detected.2

What are the warning signs of aluminum wiring problems?

Failing aluminum-wired connections seldom provide easily detected warning signs, and aluminum-wired connections and splices have been reported to fail and overheat without any prior indications or problems. CPSC's Publication 516 lists these signs of electrical system problems:1

  • hot-to-the-touch face plates on receptacles or switches
  • flickering lights
  • circuits that don't work
  • the smell of burning plastic at outlets or switches

Warning signs like warm-to-the-touch face plates on outlets or switches, flickering lights, circuits that don't work or the smell of burning plastics can indicate a fire hazard within 15- and 20-ampere aluminum wiring circuits.2 The 1974 CPSC release named the trouble signals associated with aluminum wiring problems as warm switch or receptacle face plates, a strange or distinctive odor or the smell of burning plastic in the vicinity of a receptacle or switch, and flickering of lights not traceable to appliances or obvious external causes. Where those trouble signals are present in a home, the 1974 release's advice is to seek expert advice immediately.3

For any sign of a problem, Publication 516 says to have a qualified electrician determine the cause and not to try it yourself: you could be electrocuted, or you could make the problem worse.1

How can you tell if a house has aluminum wiring?

Virtually all aluminum branch wiring was installed as plastic-sheathed cable (type NM) with no readily discernable distinction from a cable with copper conductors. Cable with aluminum conductors has "Al" or "Aluminum" and other information marked on one side of the cable jacket every few feet along its length, and those printed or embossed markings are visible in unfinished basements, attics or garages. A marking of "CU-clad" or "Copper-clad" alongside "Al" or "Aluminum" means the cable uses copper-coated aluminum wire, and that cable isn't covered by the repair recommendations in Publication 516.1

Wire size differs too: aluminum and copper-clad aluminum cables are sized at No. 10 AWG for 20-ampere circuits and No. 12 AWG for 15-ampere circuits, while copper conductors are No. 12 and No. 14 AWG.1

If you can't identify the type of wire in your home but suspect aluminum, have a qualified electrician make the determination.1 CPSC's 1974 release advised that consumers who have not had thorough electrical training should not attempt to inspect their home wiring system or make any electrical repairs or adjustments before seeking expert advice; serious or fatal electric shock could result. Where aluminum wiring was used, the 1974 release advised having the electrician check the connections on heavily loaded and constantly loaded circuits to determine whether the connections were made properly or show evidence of deterioration.3

What repairs does CPSC accept as permanent?

CPSC can recommend repair methods or products only where there is satisfactory, documented evidence that they're safe, effective and permanent: the method or product must not increase the risk of fire or other hazards, must successfully eliminate or substantially mitigate the fire hazard, and must make a permanent repair. As of the date of Publication 516, CPSC approves of only three methods for a permanent repair. If your home has aluminum wiring that hasn't been remediated, CPSC recommends a permanent repair of the connections, and Publication 516 highly recommends hiring a qualified electrician to perform the remediation.1

The three methods compare this way:1

Repair method What the work involves Who does it
Complete replacement with copper A new copper wire branch circuit system is installed, and the existing aluminum wire could be abandoned inside the walls A qualified electrician
COPALUM method A short section of copper wire is attached to the ends of the aluminum wire at every connection or splice, joined with a COPALUM crimp connector Only electricians trained by the manufacturer to use the tool
AlumiConn connector Pigtailing with a setscrew type connector instead of the COPALUM crimp connector, where the COPALUM repair isn't available A qualified electrician

Publication 516 names the aluminum wire itself as the primary cause of the potential hazards, and replacing the aluminum branch circuit conductors with copper wire eliminates that cause. How easily a qualified electrician can rewire a home depends on the home's architectural style and the number and locations of unfinished spaces like basements and attics, and for many homes rewiring with copper is impractical or prohibitively expensive.1

Pigtailing is attaching a short section of copper wire to the ends of the aluminum wire at connection points. In the COPALUM method the wires are joined with a special connector named COPALUM, and CPSC staff consider pigtailing with a COPALUM connector a safe and permanent repair of the existing aluminum wiring. The COPALUM repair should include every connection or splice involving aluminum wire in the home, including outlets, dimmers, switches, fixtures, appliances and junction boxes. Any appliance connected directly to No. 12 or No. 10 AWG aluminum branch circuit wiring must be repaired in addition to wall outlets. With short copper wire extensions at every termination throughout the home, the repaired system permits the use of standard wiring devices, including receptacles and switches.1

The COPALUM repair method has been "thoroughly proven by more than a quarter of a century of field experience," and the method has been shown to be practical for installation in an occupied and furnished home. Only electricians who are trained by the manufacturer to use the tool properly are authorized to install COPALUM connectors, and CPSC staff emphasize that the training is necessary to ensure the careful, professional workmanship the repair requires.1

CPSC staff recognize that copper replacement may be cost prohibitive and that the COPALUM repair may be unavailable in a locality. If the COPALUM repair is not available, the AlumiConn connector may be considered for a permanent repair, using pigtailing with a setscrew type connector instead of the COPALUM crimp connector. The AlumiConn connector has performed well in initial tests but is too new to have developed a significant long-term safe performance history like the COPALUM repair's, and the AlumiConn repair should be conducted by a qualified electrician.1

Other crimp connectors haven't been evaluated for connecting copper and aluminum conductors, and CPSC staff strongly recommend against their use as a repair method.1 CPSC's 2003 release said the agency believes "twist-on" connectors, receptacles and switches and other devices that connect directly to aluminum wires are an inadequate solution.2

Is aluminum wiring still considered a fire risk?

At a March 26, 2010 meeting on aluminum wiring repair recommendations, an outside attendee asked CPSC staff to revisit the assessment of small gauge aluminum branch circuit wiring as being hazardous. CPSC staff acknowledged that a comprehensive review of data had not been recently undertaken and that not all installations exhibit the same rates of failure, due to confounding factors like the properties of the particular wire. The log records that no new technical data had been presented to refute that failing aluminum wire connections are generally unstable and that overheating failure of any one of those connections poses a risk of fire ignition, so staff had no basis for reconsideration of the current recommendations. Staff also said Publication 516 was being updated to consider possible alternative repair methods.5

National Bureau of Standards report NBSIR 75-677 found that the history of events associated with aluminum electrical wiring in U.S. residences supports the view that the use of aluminum conductors in residential applications has resulted in problems. The same report found that no available field data had the characteristics necessary to develop a statistical estimate of the level of risk to consumers associated with aluminum wiring. In the report's words, existing data "cannot be used to establish that aluminum wiring presents no substantial hazard to consumers".4

In Northwood, Ohio, the city's electrical fire hazards page advises having a home checked for aluminum wiring systems and, if they're found, learning about the potential hazards, along with having electrical inspections conducted for homes 40 years and older. The same page explains that an electrical wiring fire often begins behind a wall, in a basement or in the attic, where the fire can spread throughout the home before setting off the smoke alarm or becoming evident to occupants.6

CPSC's Publication 516, releases and meeting log on aluminum wiring, a National Bureau of Standards report and Northwood, Ohio's electrical fire hazards page, checked November 2026.

Sources (6)

  1. CPSC: Repairing Aluminum Wiring, read November 25, 2026 ↑
  2. CPSC: May Is National Electrical Safety Month: Good News for Homeowners - Aluminum Wiring Fix Still Available, read November 25, 2026 ↑
  3. CPSC: CPSC Safety Recommendations For Aluminum Wiring In Homes, read November 25, 2026 ↑
  4. National Bureau of Standards: NBSIR 75-677, read November 25, 2026 ↑
  5. CPSC: Aluminum Wiring Repair Recommendations meeting log, read November 25, 2026 ↑
  6. City of Northwood, Ohio: Electrical Fire Hazards, read November 25, 2026 ↑